Need to Calibrate the TT10P Flow Meter on your Drone Cone? Here are the instructions and the owners manual for the FillRite TT10P Flow Meter that comes standard on your Drone Cone. This meter is rated up to 35 gallons per minute.
4. Fluid Calibration
Fluid calibration requires a container of a known volume
at least 5 gallons or larger that is compatible with the fluid
being metered.
A larger volume may be used and may improve calibration
accuracy, but do not exceed 99.99 units of measure.
NOTE
Before performing a fluid calibration, ensure you
have selected the closest matching CAL/Fluid factor
to ensure the best meter accuracy.
- Press the 2 & 4 buttons at the same time and hold
for 3 seconds. The display will show the firmware
version.
2. Press button 3 to enter calibration mode. The unit of
measure will be displayed.
3. Press button 3 . The display will read "FILL".
4. Now dispense fluid into your container. "FILL" will blink
on the display when fl ow is detected.
5. After dispensing fluid, press the ON button. The left
digit of the display will blink. ("00.00")
6. Press button 4 to increment the digit to the amount
of fluid dispensed (example: "05.00"). Press the ON
button to move to the right. If you make a mistake,
press button 2 to start back at the left-most digit.
7. After number is loaded, press the ON button again
to accept the entered volume.
8. Display now shows the configured CAL factor.
9. Press the ON button again and the firmware version
will be displayed.
10. Press the 2 button again to return to normal
operating mode.
Download the TT10P Owners Manual pdf here.